1,645 research outputs found

    Applying Energy Absorption Interferometry to THz direct detectors using photomixers

    Full text link
    Detector requirements for far infrared astronomy generally result in devices which exhibit a few-moded response to incident radiation. The sensitivity and spatial form of the individual modes to which such a detector is sensitive can be determined with knowledge of the complex valued cross-spectral density of the system, which we label the detector response function (DRF). A matrix representing the discretized cross-spectral density can be measured from the complex amplitudes of interference fringes generated by two identical sources as they are independently scanned through the field of view. We provide experimental verification of this technique using monochromatic THz beams generated by photomixers in which the relative phase is varied with fiber stretchers. We use this system to characterize the modal response of a single pixel from an array of microwave kinetic inductance detectors (MKIDs).Comment: in IEEE Transactions on Terahertz Science and Technology. 202

    Surface wave control for large arrays of microwave kinetic inductance detectors

    Get PDF
    Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field measurements of the MKID optical response versus the position on the array of a reimaged optical source. We demonstrate that the optical response of a detector in these arrays saturates off-pixel at the ∼−30\sim-30 dB level compared to the peak pixel response. The result is that the power detected from a point source at the pixel position is almost identical to the stray response integrated over the chip area. With such a contribution, it would be impossible to measure extended sources, while the point source sensitivity is degraded due to an increase of the stray loading. However, we show that by incorporating an on-chip stray light absorber, the surface wave contribution is reduced by a factor >>10. With the on-chip stray light absorber the point source response is close to simulations down to the ∼−35\sim-35 dB level, the simulation based on an ideal Gaussian illumination of the optics. In addition, as a crosscheck we show that the extended source response of a single pixel in the array with the absorbing grid is in agreement with the integral of the point source measurements.Comment: accepted for publication in IEEE Transactions on Terahertz Science and Technolog

    Eliminating stray radiation inside large area imaging arrays

    Full text link
    With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a point source at the pixel position is at a similar level to the stray response integrated over the entire chip area. For the antenna coupled arrays, we show that this effect can be suppressed by incorporating an on-chip stray light absorber. A similar method should be possible with the LEKID array, especially when they are lens coupled.Comment: arXiv admin note: substantial text overlap with arXiv:1707.0214

    Proof-of-Concept Demonstration of Vector Beam Pattern Measurements of Kinetic Inductance Detectors

    Get PDF
    We present results from the first vector beam pattern measurement ofmicrowave kinetic inductance detectors (MKIDs). Vector beam patterns require sampling of the E-field of the receiver in both amplitude and phase. MKIDs are inherently direct detectors and have no phase response to incoming radiation. We map the amplitude and phase patterns of the detector beam profile by adapting a two-source heterodyne technique. Our testing strategy recovers the phase information by creating a reference signal to trigger data acquisition. The reference is generated by mixing the slightly offset low-frequency signals from the output of the two synthesizers used to drive the submillimeter sources. The key requirement is that the time-series record always begins at the same set phase of the reference signal. As the source probe is scanned within the receiver beam, the wavefront propagation phase of the receiver changes and causes a phase offset between the detector output and reference signals. We demonstrated this technique on the central pixel of a test array operating at 350 GHz. This methodology will enable vector beam pattern measurements to be performed on direct detectors, which have distinct advantages reducing systematic sources of error, allowing beam propagation, and removing the far-field measurement requirement such that complicated optical systems can be measured at a point that is easily accessible, including the near field

    An Ultra-Wideband Leaky Lens Antenna for Broadband Spectroscopic Imaging Applications

    Full text link
    We present the design, fabrication and characterisation of a broadband leaky lens antenna for broadband, spectroscopic imaging applications. The antenna is designed for operation in the 300-900 GHz band. We integrate the antenna directly into an Al-NbTiN hybrid MKID to measure the beam pattern and absolute coupling efficiency at three frequency bands centred around 350, 650 and 850 GHz, covering the full antenna band. We find an aperture efficiency ηap≈0.4\eta_{ap} \approx 0.4 over the whole frequency band, limited by lens reflections. We find a good match with simulations for both the patterns and efficiency, demonstrating a 1:3 bandwidth in the sub-mm wavelength range for future on-chip spectrometers.Comment: Accepted for Publication at IEEE Transactions on Antennas and Propagatio

    Promoting physical activity in a multi-ethnic population at high risk of diabetes: the 48-month PROPELS randomised controlled trial.

    Get PDF
    BackgroundPhysical activity is associated with a reduced risk of type 2 diabetes and cardiovascular disease but limited evidence exists for the sustained promotion of increased physical activity within diabetes prevention trials. The aim of the study was to investigate the long-term effectiveness of the Walking Away programme, an established group-based behavioural physical activity intervention with pedometer use, when delivered alone or with a supporting mHealth intervention.MethodsThose at risk of diabetes (nondiabetic hyperglycaemia) were recruited from primary care, 2013-2015, and randomised to (1) Control (information leaflet); (2) Walking Away (WA), a structured group education session followed by annual group-based support; or (3) Walking Away Plus (WAP), comprising WA annual group-based support and an mHealth intervention delivering tailored text messages supported by telephone calls. Follow-up was conducted at 12 and 48 months. The primary outcome was accelerometer measured ambulatory activity (steps/day). Change in primary outcome was analysed using analysis of covariance with adjustment for baseline, randomisation and stratification variables.ResultsOne thousand three hundred sixty-six individuals were randomised (median age = 61 years, ambulatory activity = 6638 steps/day, women = 49%, ethnic minorities = 28%). Accelerometer data were available for 1017 (74%) individuals at 12 months and 993 (73%) at 48 months. At 12 months, WAP increased their ambulatory activity by 547 (97.5% CI 211, 882) steps/day compared to control and were 1.61 (97.5% CI 1.05, 2.45) times more likely to achieve 150 min/week of moderate-to-vigorous physical activity. Differences were not maintained at 48 months. WA was no different to control at 12 or 48 months. Secondary anthropometric and health outcomes were largely unaltered in both intervention groups apart from small reductions in body weight in WA (~ 1 kg) at 12- and 48-month follow-up.ConclusionsCombining a pragmatic group-based intervention with text messaging and telephone support resulted in modest changes to physical activity at 12 months, but changes were not maintained at 48 months.Trial registrationISRCTN 83465245 (registered on 14 June 2012)

    Objective cough frequency, airway inflammation, and disease control in asthma

    Get PDF
    Background Cough is recognized as an important troublesome symptom in the diagnosis and monitoring of asthma. Asthma control is thought to be determined by the degree of airway inflammation and hyperresponsiveness but how these factors relate to cough frequency is unclear. The goal of this study was to investigate the relationships between objective cough frequency, disease control, airflow obstruction, and airway inflammation in asthma. Methods Participants with asthma underwent 24-h ambulatory cough monitoring and assessment of exhaled nitric oxide, spirometry, methacholine challenge, and sputum induction (cell counts and inflammatory mediator levels). Asthma control was assessed by using the Global Initiative for Asthma (GINA) classification and the Asthma Control Questionnaire (ACQ). The number of cough sounds was manually counted and expressed as coughs per hour (c/h). Results Eighty-nine subjects with asthma (mean ± SD age, 57 ± 12 years; 57% female) were recruited. According to GINA criteria, 18 (20.2%) patients were classified as controlled, 39 (43.8%) partly controlled, and 32 (36%) uncontrolled; the median ACQ score was 1 (range, 0.0-4.4). The 6-item ACQ correlated with 24-h cough frequency (r = 0.40; P < .001), and patients with uncontrolled asthma (per GINA criteria) had higher median 24-h cough frequency (4.2 c/h; range, 0.3-27.6) compared with partially controlled asthma (1.8 c/h; range, 0.2-25.3; P = .01) and controlled asthma (1.7 c/h; range, 0.3-6.7; P = .002). Measures of airway inflammation were not significantly different between GINA categories and were not correlated with ACQ. In multivariate analyses, increasing cough frequency and worsening FEV1 independently predicted measures of asthma control. Conclusions Ambulatory cough frequency monitoring provides an objective assessment of asthma symptoms that correlates with standard measures of asthma control but not airflow obstruction or airway inflammation. Moreover, cough frequency and airflow obstruction represent independent dimensions of asthma control

    Ibrutinib Plus Venetoclax in Relapsed/Refractory Chronic Lymphocytic Leukemia: The CLARITY Study.

    Get PDF
    PURPOSE:The treatment of chronic lymphocytic leukemia (CLL) has been revolutionized by targeted therapies that either inhibit proliferation (ibrutinib) or reactivate apoptosis (venetoclax). Both significantly improve survival in CLL and replace chemoimmunotherapy for many patients. However, individually, they rarely lead to eradication of measurable residual disease (MRD) and usually are taken indefinitely or until progression. We present the CLARITY trial that combined ibrutinib with venetoclax to eradicate detectable CLL with the intention of stopping therapy. PATIENTS AND METHODS:CLARITY is a phase II trial that combined ibrutinib with venetoclax in patients with relapsed or refractory CLL. The primary end point was eradication of MRD after 12 months of combined therapy. Key secondary end points were response by International Workshop on CLL criteria, safety, and progression-free and overall survival. RESULTS:In 53 patients after 12 months of ibrutinib plus venetoclax, MRD negativity (fewer than one CLL cell in 10,000 leukocytes) was achieved in the blood of 28 (53%) and the marrow of 19 (36%). Forty-seven patients (89%) responded, and 27 (51%) achieved a complete remission. After a median follow-up of 21.1 months, one patient progressed, and all patients were alive. A single case of biochemical tumor lysis syndrome was observed. Other adverse effects were mild and/or manageable and most commonly were neutropenia or GI events. CONCLUSION:The combination of ibrutinib plus venetoclax was well tolerated in patients with relapsed or refractory CLL. There was a high rate of MRD eradication that led to the cessation of therapy in some patients. The progression-free and overall survival rates are encouraging for relapsed and refractory CLL
    • …
    corecore